The Fluke 434 II Energy Analyzer is the ideal tool for energy logging. Utilizing the new Energy Loss Calculator function, the 434 II measures the fiscal cost of energy wasted due to poor power quality. This energy monetization capability allows you to identify the most energy-wasteful areas of your facility so you can determine potential energy saving solutions. Add basic power quality measurements to the package and you’re got yourself one powerful troubleshooting tool.
Applications - Energy monetization – calculate the fiscal cost of energy waste due to poor power quality
- Energy assessment – quantify the before and after installation improvements in energy consumption to justify energy saving devices
- Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online
- Predictive maintenance – detect and prevent power quality issues before they cause downtime
- Long-term analysis – uncover hard-to-find or intermittent issues
- Load studies – verify electrical system capacity before adding loads
Features:
- Records all your necessary values in a three phase system
- Minimal setup required with intuitive menus
- Highest safety rating in the industry
- Four voltage and four current channels
- Captures waveform data on all phases simultaneously
- System-Monitor: Six power quality parameters on one dashboard
- Automatic Transient display: Never miss an event
- Auto Trend: Dont waste time setting up recordings
- Rugged, handheld recorder
- Seven hours operating time per charge on NiMH battery pack
- Transfer data files to your PC for reporting and analysis using FlukeView® software
nput characteristicsVoltage inputsNumber of inputs:4 (3 phases + neutral)
Maximum input voltage:1000 Vrms
Maximum peak voltage:6 kV
Input impedance:4 MW / 5 pF
Bandwidth:9 kHz, up to 100 kHz for transient display
Scaling:1:1, 10:1, 100:1, 1000:1 and variable
Current inputsNumber of inputs:4 (3 phases + neutral)
Type:Clamp on current transformer with mV output
Range:1 to 400 Arms with included clamps (I400S) 0.1 to 3000 Arms with optional clamps
Input impedance:50 kW
Bandwidth:9 kHz
Scaling:0.1, 1, 10, 100, 1000 mV/A and variable
Nominal frequency:40 to 70 Hz
Sampling systemResolution:16 bit analog to digital converter on 8 channels
Maximum sampling speed:200 kS/s on each channel simultaneously
RMS sampling:5000 samples on 10/122 cycles according IEC 61000-4-30
PLL synchronization:4096 samples on 10/122 cycles according IEC 61000-4-7
Display modesWaveform display:Available in Scope and Transient mode
Captures 8 waveforms simultane